We are ready for everything!
The continuous testing on our products makes our systems more and more performing.
Some examples of load tests
Glass plate alignment
This is a tooltip
The Linea Maxi canopy model has no length limits.
La Faraone designs in absolute compliance with all safety standards.
Innovation
*Maximum projection of 120 cm without snow load, 100 cm with snow load.
Anodised aluminium profile, designed to withstand 200 kg/sqm with glass up to 100 cm deep*.
*With snow load.
Anodised aluminium profile, designed to withstand 200 kg/sqm with glass up to 180 cm deep.
The continuous tests on our products make us affirm that...
THE BEHAVIOUR OF THE GLASS VARIES ACCORDING TO THE TYPE OF PLAS TIC USED FOR THE STRATIFICATION.
1. rigid interlayer | sg - sentryglas
TEMPERED LAMINATED GLASS WITH SG (SENTRYGLAS)
After breaking the two glass plates with a hammer, the plate remains almost levelled and resists an additional load of 40-50 kg/sqm.
NO MODIFICATION AT HIGH TEMPERATURES.
2. rigid interlayer | x-lab, abar or similar
TEMPERED GLASS 10+10 LAMINATED WITH X-LAB
After breaking the two glass plates with a hammer, the plate remains levelled and resists an additional load of 60-70 Kg/sqm.
NO MODIFICATION AT HIGH TEMPERATURES
TEMPERED GLASS 10+10 LAMINATED WITH ABAR (PUJOL)
After breaking the two glass plates with a hammer, the plate remains levelled and resists an additional load of 40-50 kg/sqm.
SMALL MODIFICATION AT HIGH TEMPERATURES
OTHER MODELS OF INTERLAYERS LIKE THE DG41 DO NOT BEAR ANY CHARGE AT HIGH TEMPERATURES (OVER 40˚ C). HOWEVER, AFTER BREAKING, THE GLASS DOES NOT FALL INSTANTANEOUSLY AND THOSE INTERLAYERS ALSO COMPLY WITH THE UNI 7697 NORM ON THE POST - BREAKAGE.
3. SAFE TY BOLT
SAFETY FIRST!
To complete the correct installation of the canopy, it is necessary to insert the safety bolt to block the glass in safety.
4. avoid glass COLLAPSING
THE GLASS FIXING AND RELATIVE ACCESSORIES
1. The profile must be anchored in continuity to the wall.
2. The plates must be firmly fixed in continuity to the aluminium profile with specific accessories to avoid collapsing.
5. pvb or eva on linea
TEMPERED LAMINATED GLASS WITH PVB OR EVA
After breaking the two glass plates with a hammer, they fall instantly down!
IF YOU WANT TO USE THIS TYPE OF GLASS, YOU NEED TO POSITION THE CANOPY AT 2 m ABOVE THE GROUND + THE LENGTH OF THE PROJECTION OF THE GLASS IN A WAY THAT, BY FALLING , IT DOES NOT HIT ANY PERSONS.
IT DOES NOT COMPLY WITH THE UNI 7697 NORM ON
THE POST-BREAKAGE .
2 broken 10+10 glass plates.
6. Double fixing
WITH THE SNOW LOAD AND/OR THE WIND PRESSURE IN DEPRESSION, THE ACTION ON FASTENERS CAN REACH HIGH VALUES.
We need a profile with a larger contact base on the support, with two rows of fasteners, that avoids the “hinge” effect and reduces the effort on the single fixing.
ATTENTION:
MAKE SURE THAT YOU PERFORM A SAFE FIXING ON THE WALL. A SINGLE LINE OF CENTRAL FIXINGS CAUSES THE “HINGE” EFFECT.
This is the first Faraone test in 2011, which was immediately put aside
because it gave no security. Subsequently, the double-fixed Linea canopy was designed.
Transmission diagram
of gravity loads
Transmission diagram
of the wind pressure in depression
Transmission diagram
of gravity loads
Transmission diagram
of the wind pressure in depression
The test reports of the Faraone canopies
Request the test report.
The Faraone canopy systems are designed to counteract static stress, snow load, and those dynamics due to wind forces.
The canopy tests are made on reinforced concrete beams, on solid masonry and on steel beams with relative chemical
anchorages depending on the intended use, obtaining the maximum possible safety .
Attention!
For the choice of anchoring on the masonry or the load-bearing holes, you need to check the type of wall with a professional designer.
The test certificate has no validity if the installation is not done as
described in the catalogue, and if the provided fixing screws are not
used as indicated.
For fixing to the wall, use only certified screws as supplied or indicated.
FARAONE canopies are designed to reach and exceed a load of 300 kg/sqm:
Colour range of the aluminium profile
Silver anodised aluminium, satin finishing.
In stock.
RAL 9010
polished white aluminium.
30 DAYS delivery.
RAL colours.
On request only for a minimum quantity of 10 METERS.
Delivery: 45 days.